 sales@drjscientific.com      0086-18352836805
You are here: Home / Products / Hide / High Frequency Infrared Carbon Sulphur Analyzer for Battery Materials

Product Category

Contact Us

Hot-Selling Products

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button

High Frequency Infrared Carbon Sulphur Analyzer for Battery Materials

Carbon: 0.00001%~99.99999%
Sulfur: 0.00001%~99.99999%
Integration, super light
High availability, low cost
Long service life, high stability of product
Unique analysis of gas removal device
Full scale linear calibration
Constant temperature of high-temperature furnace
Carbon monoxide conversion
Weak signal detection technology
Availability:
Quantity:

Summary:

CS-8820S High Frequency Infrared Carbon Sulphur Analysis is suitable for multi field and all around. Carbon and sulphur analyzer combines with high-frequency induction burner, it is a high-tech product the which based on light, machine, electricity, computer, analytical skills, it has characteristics of wide measuring range and the results of analysis is accuracy and reliable. Because of adopting computer technology, intelligent equipment, screen display, text and data collection, deal with problems and so on have reached the advanced the world level, more industries detect carbon and sulfur elements in this analysis equipment. The key components adopt high quality elements to ensure the instrument stability and high quality.


Application:

CS-8820S High Frequency Infrared Carbon Sulphur Analysis is used to measure mass fraction of carbon and sulphur in steel, iron, alloy, casting core sand, nonferrous metals, cement, ore, coke, catalyst, magnetic materials, ceramics, inorganic matter, graphite, refractory materials, battery materials, plants and other materials. And mainly used in new energy, metallurgy, mechanical, mine, inspection, nuclear industry, coal, automobile, shipping, aviation, food, aerospace, building materials, university, geology, petrochemical and so on.


Features:

Infrared detect system

The core component of infrared detection pool adopts precious metal miniature infrared light source which is high efficient and long service life. The modulation system adopts high-precision stepper motor control by the micro controller. It is realized that long-term stability of the modulation frequency and infrared pyroelectric solid light cone sensor, Narrowband filters, these instruments make the host in high detect sensitivity, and it is effective way to detect carbon and sulfur content (ppm). it simplifies the hardware design, adding the whole host reliable and anti-interference ability.
1.The circuit design: the whole machine adopts modular design, highly integrated electronic circuits, it is very stable and reliable, meanwhile, it is adopted multi-level isolation so as to resolve high frequency interference thoroughly.
2.Sampling: it is adopted 32-bit sampling chip which belongs to America Analog DCvices Company so it has fast speed and high precision.
The Communication: it is adopted USB new data exchange technology, so it greatly improves the communication speed.
The Power Supply: it is adopted high quality linear integrated military-grade power module, its output stable and there is no problem.
3.Light Source: special new type platinum infrared light source, it is efficient and its spectral stability.
4.The Analysis of pool: Gold-plated carbon and sulfur analysis pool and High-precision pyroelectric infrared detector.
5.The Motor: special aviation motor, its thermal stability well, it has a long service life.

High Frequency Burning System
1.High Frequency Circuit: it is adopted Self-excited directional coupler take power feedback, it ensures that output power is consistent, and it makes samples fully burned. It is stable.
2.High-frequency High Power Circuit Design: it is adopted 7.5kvA high-frequency pipe( actually its use power more than 2.5kvA, can not add sample with empty burn), it is reduced the load on high-frequency combustion systems, and it improves service life.
3.Military Products: Ceramic high-power tube and ceramic vacuum capacitor (100A)。
4.High-frequency furnace output is power and power adjustable, it is suitable for all kinds of sample combustion analysis, a wide range of test materials, the whole machine adopts Import solenoid valve, high-frequency Ceramic power tube etc.
5.It adopts automatic cleaning of the burner and clean it up.
6.The control by electronic flow, the analysis of gas flow volume, the analysis of result is more stable and reliable.
7.The dust clean in the tube so as to improve measurement stable and precision.
8.The internal oxygen purification has advantages of analysis low content.
9.The main circuit overcurrent and timeout protection. When the loop current exceeds desired point or burning time more than 60s, the system cut the main circuit by itself, and this system can avoid high-power devices overheating damage, eliminating security risks. When the status of overcurrent disappears, the main circuit automatically resume normal.
10. The system of high-frequency combustion and infrared detection system adopt fiber connection, cutting off  direct electrical connection between the two, avoiding the burning furnace or external circuit can produce interference by cable transfers to infrared monitoring system and improves the data stable.

The Random Software
1.It is adopted WINDOWS XP color surface in Chinese/English, its interface clear and its operation very convenient.
2.The independent infrared analysis software, complete functions. It has the functions of channel selection, data statistics, breakpoint correction, results corrected, the system of detecting, system diagnostics and more than forty functions.
3.The analysis process of dynamic data integration, sampling every 32 time, A/D change the frequency 150Hz-200Hz and it improves the analysis of sensitivity and accuracy.
4.The signal is tracked and its adjusted by itself.
5.Linear table of linear data high, medium and low can be corrected.
6.The process of analysis displays all kinds of real-time data and carbon and sulfur release curve.
7.There are 20 analysis channels to choose( each carbon and sulfur channels), and they can be arbitrary collocation, the choose range is very wide.
8.There are 100 carbon and sulfur release curves( each 50), it is can be stored at any time, and can be complete with carbon release curve and sulfur release curve.
9.Linearization calibration technology in full range, there are single and multi-point calibration, it can be set up one , two, three and more Linear calibration equation, and it improves Linear calibration equation and the correction of analysis data.
10.It can be communicated with data center or reported in front of the furnace.
11.Any brand of computers can communicate with this system.
12.A variety of print output mode.
13.It can communicate with any brand of electronic balance.



Parameter


Item

Index

Measurement Range

Carbon: 0.00001%~99.99999%

Sulfur: 0.00001%~99.99999%

Analysis Error

Up to standard of GB/T20123-2006/ISO15350: 2000

Analysis Time

Adjustable within 25-60 s (Normally around 35 s)

High-Frequency Furnace

Power≥2.5kVA, Frequency: 18MHz

Electronic Scales

Non-quantitative weighing, Reading Precision:0.0001g

Working Environment

Room Temperature: 10-30℃, Relative Humidity: Less than 90%

Power Supply

It is required to keep good earthing. Voltage AC220V±5%, Frequency 50Hz±2%

Oxygen

Purity≥99.5%, Input Pressure: 0.18MPa±5%



Previous: 
Next: 
Chemical, physical and structural,
cleanliness analysis solution supplier
Nowadays we help users better understand a wide variety of materials, from polymers and mining to metals and from electronic chip to component.

QUICK LINK

PRODUCTS

CONTACT
  0086-18352836805
  sales@drjscientific.com
 0086-18352836805
 No. 35 Jingsheng Rd., Huishan District, Wuxi City, Jiangsu Province, China.
Copyright © 2021 Dr.J Scientific